Hi,
I am at the setup stage of running Prolint 74 in OpenEdge Developer Studio (Open Edge 11.5 - 64 bit).
Proparse.net loads properly.
The Prolint screen starts. When I add files to be tested and press OK the error 6087 is displayed when it hits the procedure control-load in prolint/outputhandlers/logwin.w.
Please, help - Hanna
Comments
seems like you are trying to
seems like you are trying to load a 32 bits OCX within a 64 bits session...
Prolint 74 in Open Edge 11.5 - 64 bit doesn't work with ActiveX
Jice,
This is MSCOMCTL.OCX file. Apparently it is identical for 32 and 64 bits. It in registered as \Windows\SysWOW64\MSCOMCTL.OCX.
I tried all tricks with registering and unregistering which I could find.
I am coming to the point that ACTIVEX doesn't work with Openedge 11.5!?
If I change Prolint logwin.w (newer Prolint procedure with ACTIVEX) to logwin8.w (older version which doesn't use ACTIVEX) it works.
Hanna